Bug Report
-
Resolution: Fixed
-
L3 - Default
-
None
Problem:
- given:
- I have a Camunda Engine/Platform running with basic authentication enabled
- I run Optimize 2.2 and configure basic authentication to the engine with a user that has permissions as described here
- when:
- I start Optimize and try to log in with a valid user that has access to Optimize configured
- then:
- I get an error that the user does not have the correct rights
- expected:
- I can access Optimize
- Optimize has all engine data imported
AT:
- it is documented that the user for basic authentication against the platform also needs Read permission for Authorizations and Users
- this is back-ported up to Optimize 2.1 documentation
This is the controller panel for Smart Panels app
[OPT-1968] Documentation on which authorizations the user for basic authentication needs is incomplete
Link | New: This issue is related to SUPPORT-5446 [ SUPPORT-5446 ] |
Labels | Original: current_release | New: SUPPORT current_release |
Fix Version/s | New: 2.4.0 [ 15365 ] |
Description |
Original:
* given:
** I have a Camunda Engine/Platform running with basic authentication enabled ** I run Optimize 2.2 and configure basic authentication to the engine with a user that has permissions as described [here|https://docs.camunda.org/optimize/2.2/technical-guide/configuration/] * when: ** I start Optimize and try to log in with a valid user that has access to Optimize configured * then: ** I get an error that the user does not have the correct rights * expected: ** I can access Optimize ** Optimize has all engine data imported *AT:* * it is documented that the user for basic authentication against the platform also needs Read permission for Authorizations and Users * this is back-ported up to Optimize 2.1 documentation |
New:
*Problem:*
* given: ** I have a Camunda Engine/Platform running with basic authentication enabled ** I run Optimize 2.2 and configure basic authentication to the engine with a user that has permissions as described [here|https://docs.camunda.org/optimize/2.2/technical-guide/configuration/] * when: ** I start Optimize and try to log in with a valid user that has access to Optimize configured * then: ** I get an error that the user does not have the correct rights * expected: ** I can access Optimize ** Optimize has all engine data imported *AT:* * it is documented that the user for basic authentication against the platform also needs Read permission for Authorizations and Users * this is back-ported up to Optimize 2.1 documentation |
Link | New: This issue is related to SUPPORT-5438 [ SUPPORT-5438 ] |
Status | Original: Open [ 1 ] | New: In Specification [ 10000 ] |
Status | Original: In Specification [ 10000 ] | New: In Development [ 10312 ] |
Assignee | Original: Johannes [ johannes.heinemann ] | New: Sebastian Bathke [ sebastian.bathke ] |
Status | Original: In Development [ 10312 ] | New: In Review [ 10212 ] |