Uploaded image for project: 'camunda BPM'
  1. camunda BPM
  2. CAM-1449

I can deploy message start & message intermediate events with same messageName

      AT:

      • It should be possible to use the same messageName for a message start event and a message intermediate event in
      • a single process definition
      • multiple process definitions
      • multiple process defintion level start events with the same message name are still unsupported.

        This is the controller panel for Smart Panels app

            [CAM-1449] I can deploy message start & message intermediate events with same messageName

            Daniel Meyer created issue -

            Daniel Meyer added a comment -

            Also look at CAM-1448

            Daniel Meyer added a comment - Also look at CAM-1448
            Daniel Meyer made changes -
            Link New: This issue is related to CAM-1448 [ CAM-1448 ]
            Daniel Meyer made changes -
            Description Original: AT:
            - It should be possible to use the same messageName for a message start event and a message intermediate event in
              a) a single process definition
              b) multiple process definitions

            - multiple start events with the same message name are still unsupported.
            New: AT:

            * It should be possible to use the same messageName for a message start event and a message intermediate event in
              * a single process definition
              * multiple process definitions

            * multiple start events with the same message name are still unsupported.
            Robert Gimbel made changes -
            Fix Version/s New: 7.2.0 [ 12997 ]
            Fix Version/s Original: 7.1.0 [ 12891 ]
            Daniel Meyer made changes -
            Link New: This issue is related to CAM-1776 [ CAM-1776 ]
            Robert Gimbel made changes -
            Fix Version/s Original: 7.2.0 [ 12997 ]
            Roman Smirnov made changes -
            Link New: This issue is related to CAM-3741 [ CAM-3741 ]

            meyer I assume, the last bullet point addresses two process definitions with the same start message name, right? cf CAM-3741

            Thorben Lindhauer added a comment - meyer I assume, the last bullet point addresses two process definitions with the same start message name, right? cf CAM-3741
            Daniel Meyer made changes -
            Description Original: AT:

            * It should be possible to use the same messageName for a message start event and a message intermediate event in
              * a single process definition
              * multiple process definitions

            * multiple start events with the same message name are still unsupported.
            New: AT:

            * It should be possible to use the same messageName for a message start event and a message intermediate event in
              * a single process definition
              * multiple process definitions

            * multiple process defintion level start events with the same message name are still unsupported.

              thorben.lindhauer Thorben Lindhauer
              meyer Daniel Meyer
              Votes:
              0 Vote for this issue
              Watchers:
              6 Start watching this issue

                Created:
                Updated:
                Resolved: