Reproduce steps:
1.) create signavio connector with our camunda web modeler (vm2)
2.) create filesystem connector
3.) roundtrip file 'SUPPORT-781' from signavio through filesystem
After the roundtrip all extension elements are lost.
I also attached the following 2 bpmn files:
before_roundtrip: bpmn file export from our camunda web modeler
after_roundtrip: bpmn file from cycle roundtrip
This is the controller panel for Smart Panels app
[CAM-1635] cycle pool extraction removes extension elements
Link | New: This issue is related to SUPPORT-781 [ SUPPORT-781 ] |
Labels | New: EasyPick |
Rank | New: Ranked higher |
Rank | New: Ranked lower |
Status | Original: Open [ 1 ] | New: In Progress [ 3 ] |
Assignee | New: Nico Rehwaldt [ rehwaldt ] |
Assignee | Original: Nico Rehwaldt [ rehwaldt ] | |
Resolution | New: Fixed [ 1 ] | |
Status | Original: In Progress [ 3 ] | New: Resolved [ 5 ] |
Remaining Estimate | New: 0 minutes [ 0 ] | |
Original Estimate | New: 0 minutes [ 0 ] |
Assignee | New: Daniel Meyer [ meyer ] |
Problem was: extension elements were explicitly excluded during pool extraction. Looks as if this was an acceptance criteria some time ago.
Still needs to be backported to `7.0.5`.