      • given:
        • Engine and Optimize are up, configured and running
        • I am an admin user and created a report for "invoice" process and place it on a dashboard.
        • I give user john permission for "READ_HISTORY" for all process definitions, but not for "invoice" process.
      • when:
        • I log-in with user john
        • I try to open the dashboard that admin has created with the report of which I am not allowed to see the content
      • then:
        • Optimize front crashes and I see "Cannot read property view of undefined"
      • expected:
        • john should be able to see the dashboard, but not the report / data of the report

      Hints: Also the whole report disappears from the report list for john.