Combined report shows always relative value of 100%

XMLWordPrintable

    • Icon: Bug Report Bug Report
    • Resolution: Fixed
    • Icon: L3 - Default L3 - Default
    • 2.6.0-alpha1, 2.6.0
    • None
    • frontend
    • None

      • given:
        • I create two reports that are both showing the process instance count grouped by none
      • when:
        • I combine these two reports to a combined report
        • I hover over the entries or activate the "Show Relative Value" tooltips
      • then:
        • The relative value is 100% for all reports
      • expected:
        • only the absolute value is shown
        • it is not possible to show the relative value from the configuration menu

      Background:
      The relative value always corresponds to the number of instances in the original report. Since the number of instances between the reports in a combined report can be different, this value can be confusing.