      Steps to reproduce:

      1. Logout of the web app
      2. Paste a deep link into the browser's URL input field
        (like http://localhost:8080/camunda/app/cockpit/default/#/process-definition/invoice:3:fd3ce327-0226-11ea-adcb-0c54150ec03b/runtime?searchQuery=%5B%5D&viewbox=%7B%22sid-0b0aaa25-3baf-4875-9d7a-0907d599a9ef%22:%7B%22x%22:-681.2608695652174,%22y%22:-6.001499250374812,%22width%22:2371.814092953523,%22height%22:634.1829085457271%7D%7D)
      3. login to the web app

      Observed behavior:

      • After login, the user is redirected to the start page and not to the page provided in the URL.

      Expected behavior:

      • After login, the user is redirected to the page provided in the URL.

      Hints:

      • In the case of the Tasklist, the deep link brings the user directly to the given user task.