Uploaded image for project: 'camunda BPM'
  1. camunda BPM
  2. CAM-11954

In Webapps, historic instance permission check is missing

XMLWordPrintable

    • Icon: Bug Report Bug Report
    • Resolution: Fixed
    • Icon: L3 - Default L3 - Default
    • 7.14.0, 7.13.1, 7.14.0-alpha1
    • 7.13.0, 7.14.0
    • webapp
    • None

      Steps to reproduce

      1. Enable historic instance permissions
      2. Grant only read permission to the process definition and a specific historic process instance
      3. Go to ...
        • history definition view and check the historic process instance tab
        • history instance view and check historic incident tab or historic called instances tab

      Expected behavior

      • On definition view, the historic process instance with granted read permission is shown
      • On instance view, the related historic incidents & historic called instances are shown

      Observed behavior

      The tabs remain empty.

      Hint
      The auth check is missing for the private Webapp REST API

       

        This is the controller panel for Smart Panels app

              Unassigned Unassigned