On Tomcat, process engines are not properly shut down when the defining application is undeployed

    XMLWordPrintable

    Details

    • Type: Bug Report
    • Status: Closed
    • Priority: L3 - Default
    • Resolution: Fixed
    • Affects Version/s: None
    • Fix Version/s: 7.0.0-alpha1, 7.0.0
    • Component/s: engine
    • Labels:
      None

      Description

      To reproduce:

      • run integration test suite in tomcat6 profile
      • org.camunda.bpm.integrationtest.functional.metadata.engine.TestProcessEnginesXmlInLibrary fails, because an engine with the same name is created in the previous test, org.camunda.bpm.integrationtest.functional.metadata.engine.TestMultipleProcessEnginesXmlsInLibrary