Uploaded image for project: 'camunda BPM'
  1. camunda BPM
  2. CAM-4866

Failing Job Lock Time is not save correctly during Daylight Saving Hour

    XMLWordPrintable

    Details

      Description

      If a retry cycle is used during the daylight saving hour, so for example the clock will be set back by one hour, the calculated lock time seems incorrect saved to the database.

      So if the lock time would be in the 02:25:00 CEST it is persisted as 02:25:00 CET.

      See failing test case:
      https://github.com/camunda/camunda-bpm-platform/commit/195d0b194785f4da08d0bd4338cede22190006db

        Attachments

          Issue Links

            Activity

              People

              Assignee:
              nikola.koevski Nikola Koevski
              Reporter:
              sebastian.menski Sebastian Menski
              Votes:
              0 Vote for this issue
              Watchers:
              7 Start watching this issue

                Dates

                Created:
                Updated:
                Resolved: