Uploaded image for project: 'camunda BPM'
  1. camunda BPM
  2. CAM-5524

Retry time cycle is not recognized on async events

XMLWordPrintable

    • Icon: Bug Report Bug Report
    • Resolution: Duplicate
    • Icon: L3 - Default L3 - Default
    • None
    • None
    • engine
    • None

      Problem:
      Whenever an event is set to be async (ie. async before or async after) a given custom retry time cycle is not recognized. The custom retry time cycle is only recognized if the event is a timer event.

      Expected behavior:
      A given custom retry time cycle is also recognized on async events.

      Hint:
      The parsing of the retry time cycle happens in the FaxFailedJobParseListener

        This is the controller panel for Smart Panels app

              Unassigned Unassigned
              roman.smirnov Roman Smirnov
              Votes:
              0 Vote for this issue
              Watchers:
              3 Start watching this issue

                Created:
                Updated:
                Resolved: