Uploaded image for project: 'camunda BPM'
  1. camunda BPM
  2. CAM-8737

Joining inclusive gateway does not wait for all incoming flows

    XMLWordPrintable

Details

    Description

      Steps to reproduce
      1. Deploy and start the process from attachment.
      2. Send message 'message1'.

      Current result: Token from bottom execution passes joining inclusive gateway till the end event node.

      Expected result:
      Token from the bottom execution waits for token from the upper execution, before passing inclusive gateway.