Uploaded image for project: 'camunda BPM'
  1. camunda BPM
  2. CAM-8906

In Cockpit, User Operation Log is not deterministic

    XMLWordPrintable

Details

    • Bug Report
    • Resolution: Fixed
    • L3 - Default
    • 7.9.0, 7.9.0-alpha4
    • 7.9.0-alpha3
    • cockpit
    • None

    Description

      Steps to reproduce:
      1) deploy a process with two user tasks
      2) start an instance of that process
      3) go to cockpit
      4) select the started process instance
      5) assign the pending user task to "demo"
      6) modify the process instance (move to token to second user task)
      7) open user operation tab in historic process definition view

      Observed Behavior:

      Expected Behavior:

      • The user operation log shows always the same.

      Hint:

      • The implementation [1] does not respect that multiple user operation can have the same operation id but different operation types.

      [1]: https://github.com/camunda/camunda-bpm-platform-ee/blob/f1683c519fbf7ebecddb16d0512713790761b0af/webapps/camunda-webapp/plugins/src/main/resources-plugin/cockpit/history/app/components/userOperationsTable.js#L49-L65