      Given:
      A process instance with a resolved and open incident on the same activityInstance

      When:
      I create an incident count report with either a resolved or open flow node filter

      Then:
      The incident counts span both resolved & open incidents

      Expected:
      the counts should only contain the incident instances with the filtered state

      Hint:
      Afaiu the issue is that GroupByIncidentFlowNode currently does not contain a filter aggregation to apply the view level filter, so effectively there is no view level filter applied, see attached incidentReportWithStateFilter.json. I manually added a filter aggregation in incidentReportWithStateFilter_aggregationFilter.json which then yielded expected results.