ISO-8601 specifies two patterns for durations:
P[n]Y[n]M[n]DT[n]H[n]M[n]S
and
P[n]W
see https://en.wikipedia.org/wiki/ISO_8601#Durations
The engine does not support the second pattern (P[n]W).
Expected behavior:
P[n]W is supported like specified in ISO-8601
This is the controller panel for Smart Panels app
- duplicates
-
CAM-10759 Unable to use timer duration of weeks, days work
-