Changes to select control of the embedded form are not detected after browser refresh

    XMLWordPrintable

Details

    • Bug Report
    • Resolution: Fixed
    • L3 - Default
    • 7.17.0, 7.17.0-alpha5
    • 7.16.0
    • tasklist
    • None

    Description

      Environment (Required on creation): camunda-bpm-run-7.16.0

      Description (Required on creation; please attach any relevant screenshots, stacktraces, log files, etc. to the ticket):

      Steps to reproduce (Required on creation):

      1. select a task in the tasklist (with an embedded form, see attached)
      2. select some value on a select control of the embedded form
      3. refresh the browser page
      4. select another value on the same select control of the embedded form

      Observed Behavior (Required on creation):

      Change on a select control is not detected, the Save button is not enabled. Please see attached reproduction GIF.

      Expected behavior (Required on creation):

      The change on a select control is detected. It should be possible to continue saving changes after refreshing the browser or logout/login Camunda.

      Root Cause (Required on prioritization):

      When a form field of type select is used, the logic of the directive camVariableType is first executed initially and executed again when the form field's value is set (cf. choices-field-handler.js [1]) via a saved value or from a variable. In the first run, $pristine is false, but in the second run, it is true (due to setting the respective option from the saved state or fetched from a form variable). When $pristine is true, the camVariableType directive changes $pristine to false and $dirty to true (cf. angularjs/forms/index.js [2]). This makes the select dirty even though the user didn't touch it. This, in turn, leads to the described bug. Since $dirty was set programmatically, changing the select does not change the dirty state for the entire form, so the Save button remains disabled.

      Solution Ideas (Optional):

      Remove logic to programmatically make input fields dirty.

      Hints (optional):

      Changes to other controls are detected after the refresh.

      [1] https://github.com/camunda/camunda-bpm-platform/blob/cab885/webapps/camunda-bpm-sdk-js/lib/forms/controls/choices-field-handler.js#L130
      [2] https://github.com/camunda/camunda-bpm-platform/blob/cab885/webapps/camunda-bpm-sdk-js/lib/angularjs/forms/index.js#L65-L70

      mgm-controller-panel

        This is the controller panel for Smart Panels app

        Attachments

          1. diagram_1.bpmn
            2 kB
          2. reproduction.gif
            reproduction.gif
            371 kB
          3. test_form.html
            1 kB

          Activity

            People

              hariharan.parasuraman Hariharan Parasuraman
              Alex_Voloshyn Alex Voloshyn
              Tassilo Weidner Tassilo Weidner
              Daniel Kelemen Daniel Kelemen
              Votes:
              0 Vote for this issue
              Watchers:
              2 Start watching this issue

              Dates

                Created:
                Updated:
                Resolved:

                Salesforce