Uploaded image for project: 'Camunda Optimize'
  1. Camunda Optimize
  2. OPT-4562

Report Configuration cannot be changed after too many buckets error

    XMLWordPrintable

Details

    • Bug Report
    • Resolution: Fixed
    • L3 - Default
    • 3.3.0-alpha2, 3.3.0
    • None
    • None
    • None
    • Not defined

    Description

      Given:
      A Process Instance Count, Group By Variable, distributed by start Date (automatic) report.

      When:
      I activate custom bucketing and hit the too many buckets exception introduced with OPT-4338
      Alternatively:
      I open a stored report that hits the bucket exception error

      Then:
      I get the error message which tells me about the too many buckets problem but I cant disable/change the bucket settings as the configuration menu is disabled/Or not event edit the report in case of an evaluation by id.

      Expected:
      I can open the configuration menu and change the setting/Open the saved report and change the configuration

      mgm-controller-panel

        This is the controller panel for Smart Panels app

        Attachments

          1. evaluateReportByIdBucketException.png
            133 kB
            Sebastian Bathke
          2. tooManyBuckets_1.png
            79 kB
            Sebastian Bathke
          3. tooManyBuckets_2.png
            52 kB
            Sebastian Bathke

          Activity

            People

              Unassigned Unassigned
              sebastian.bathke Sebastian Bathke
              Votes:
              0 Vote for this issue
              Watchers:
              1 Start watching this issue

              Dates

                Created:
                Updated:
                Resolved: