    Type:
Bug Report
 - 
    Resolution: Fixed
 - 
    Priority:
L3 - Default
 - 
    Affects Version/s: None
 - 
    Component/s: cockpit
 - 
    None
 
Duration report does not show a proper error message for authorization exceptions.
Precondition
- User has no READ_HISTORY authorization for any ( * ) Process Definitions
 
Steps to reproduce
- In Cockpit click in the top navigation on "more" -> "Reports" -> "Process Instance Duration
 
Observed behavior
- A red blank box without further information is shown
 
Expected behavior
- A proper error message is shown
 
AT
- An error message displays that the user has not the right authorization to see the report
 
This is the controller panel for Smart Panels app
- is related to
 - 
                    
CAM-8026 I can only create a report when the user has read access to all processes
-         
 - Closed
 
 -